Specifications
Waste Water Evaporation Water Treatment Water Mister System
Evaporator Power Consumption
The following is actual loaded fan operation data collected by AC Electric at our request to determine actual power consumption. This test utilized a chart recorder and the following summary is from information taken from that chart recorder.
Listed below is record 51 as an average record.
| AMP | KW | POWER FACTOR | VOLT | KVA CODE | EFFICIENCY @ OPERATING |
| 23.49 | 10.45 | .99 | 450 | G | 94.2 |
USEFUL FORMULAS
FORMULAS FOR ELECTRICAL CIRCUITS
| TO FIND | DIRECT CURRENT | SINGLE PHASE | THREE PHASE |
| AMPERES | Watts/volts | Watts/volts x Power factor | Watts/1.732 x Volts x Power factor |
| VOLT-AMPERES | ----------- | Volts x Amperes | 1.732 x Volts x Amperes |
| WATTS | Volts x Amperes | Volts x amperes x power factor | 1.732 x Volts x Amperes x power factor |
FORMULAS FOR ELECTRIC MOTORS
| TO FIND | DIRECT CURRENT | SINGLE PHASE | THREE PHASE |
| HORSEPOWER | E x I x EFF/746 | E x I x EFF x PF/746 | 1.732 x E x I Xeff x PF / 746 |
| CURRENT | 746 x HP/E Xeff | 746 x HP/ E x EFF x PF | 746 x HP/ 1.732 x E x EFF XPF |
| EFFICIENCY | 746 X hp/E x I | 746 x HP/E x I x PF | 746 x HP/1.732 x E X I XPF |
| POWER FACTOR | ---------- | Input watts/ E x I | Input Watts/1.732 x E x I |
E = Volts I = Amperes
EFF = Efficiency (decimal) PF = Power Factor (decimal)
HP = Horsepower
Utilizing these formulas allow us to determine the operational cost of running our motor which has a plated horse power of 40 but actually operates at 23 horsepower as you shown on the following page, using our chart recorder figures to do the calculations.
Click Here for more information on the Power Consumption of the Turbomist S30 Evaporator