EVAPORATOR SOUND TEST

Technician: Gordon Spelay

Test date: February 16, 1999

Location: AC Motor Electric, Penticton, BC

Weather conditions: Overcast and calm

Meter: No. 33-2055

Distance from the evaporator in feet Readings in db’s
0 ft 99 db
5 ft 98 db
25 ft 93 db
50 ft 89 db
75 ft 85 db
100 ft 75 db
200 ft 65 db


NOTES

1. Test site was flat and unobstructed.

2. Test readings were also taken from behind surrounding buildings at a distance of approximately 150 feet. These reading ranged from 65 Db to 75 db.

3. Normal speech pattern will register between 65-70 db’s.